Hydraulic Testers PPC Pad

Detailbild


Left column (copy 2)

Product Video

Discover the easy handling and flexible usage of our Hydraulic testers of the PPC series. 

Learn more about these testing devices on our special microsite. Pls. click here

product video ppc en (copy 1)


Left column (copy 2)

Hydraulic Testers PPC-Pad

The PPC Pad is the highest-performance unit of the PPC series. This portable multi-function hand-held measuring instrument has been especially developed for the increasing fluid technology requirements. STAUFF‘s CAN bus sensors take advantage of the bus system‘s automatic sensor recognition to provide an easy-to-install Plug & Play solution. The measured values can be displayed in various presentation styles and make effective solutions-orientated analysis possible.

Left column (copy 2)

Features

▪ Portable multi-function hand-held measuring instrument
▪ Pressure, temperature, flow and speed can be measured,
  monitored and analysed
▪ Measurement and display of over 50 channels
▪ Measured value display: numerical, bar graph, pointer,
  curve graph
▪ Project templates can be saved and loaded
▪ Interfaces: CAN, LAN, USB
▪ Total memory with up to 1 billion measured values
▪ Measured data can be (automatically) recorded, saved and
  analysed with the PPC-Soft-plus PC software and a LAN or
  USB connection
▪ Max. CAN bus length: 100 m / 328 ft
▪ Calibration certificate on request
  (only for PPC-Pad-102/-103)

Technical Data

Materials
▪ Housing: ABS/PC (Thermoplastic)
▪ Protective Sleeve: TPE (Thermoplastic Elastomer)

Dimensions and Weight
▪ WxHxD: 257 x 181 x 75 mm / 10.12 x 7.13 x 2.95 in
▪ Weight: 1550 g / 3.4 lbs (basic model)

Display
▪ FT-LCD colour graphic display
▪ Visible area: 115 x 86 mm/ 4.53 x 3.39 in
▪ Resolution: 640 x 480 Pixel

Functions
▪ Measurement: ACT/MIN/MAX values
▪ Measured value display: Numerical, bar graph,
  pointer, curve graph
▪ Measuring functions: Start/stop, points, trigger
▪ Trigger: Slope, manual, level, window, time, logic
  (interconnection of up to two events for the
  measurement start and stop)
▪ Pre-trigger
▪ Remote operation via the Ethernet
▪ Acoustic notification at any incident

Measured Data Memory
▪ For storing measured values, project data and screenshots

▪ Memory capacity: ≤4 million measured values per
  measurement
  Total measured value memory >1 billion measued values
▪ Memory format: ACT/MIN/MAX
▪ Memory interval: 1 ms to 24 h
▪ Memory duration: 1 ms to 300 h (trigger measurement)
▪ Internal: 64 MB (approx. 32 million measured values)
▪ External SD memory: MicroSD memory card incl. in
  standard shipment
  Slot: MicroSD memory card
▪ External USB mass memory device: up to 40 GB

Left column (copy 2)

Inputs / Outputs
▪ CAN sensor inputs: 2 CAN bus networks each with
  8 sensors and max. 16 channels (for STAUFF CAN bus
  sensors)
  Scanning rate: 1 ms = 1000 measured values/sec.
  M12x1 push-in connector, 5-pin with SPEEDCON
▪ 1 digital trigger input: Scanning rate: 1 ms
  Input impedance: 1 kΩ
  Active high: >+7 … +24 V DC
  Active low: <1 V DC isolated
▪ 1 digital trigger output: Scanning rate: 1 ms
  Max.switching signal: +24 V DC/max. 20 mA isolated
▪ Push-in connector for digital input and output:
  M8 x 1 / 4-pin, push-in connector

Power Supply
▪ Internal: Lithium Ion pack, +7.4 V DC / 4500 mAh
  Battery charging circuit/operating time with 3 CAN
  sensors: > 8 h

Protection Rating
▪ IP64: Dust tight and protected against splashing water

Technical Data (for PPC-Pad-102 and 103)

Input with Sensor Recognition
▪ 3 or 6 sensor inputs (up to 6 or 12 analogue measurement
  channels) with sensor recognition (p/T/Q/n) for PPC
  sensors
▪ Push-in connection: 5-pin, push-pull, combination
  panel plug/socket
▪ Scanning rate: 1 ms = 1000 measured values/sec.

▪ For the combined Pressure/Temperature Sensor,
  there is an additional temperature channel for each sensor
  input
▪ Temperature scanning: 1 s

Inputs for Auxiliary Sensors
▪ 2 analogue sensor inputs: for measuring current and
  voltage
  Scanning rate: 1 ms = 1000 measured values/sec.
  Voltage measuring range:
  -10 … +10 V DC (freely configurable)
  Current measuring range: 0/4…20 mA
  Supply external sensors: +18 … +24 V DC/max. 100 mA
  Push-in connection: M12x1, 5-pin socket

▪ FAST mode: Scanning rate: 0.1 ms = 10000
  measured values/sec. only one auxiliary sensor input
  is useable

Accuracy
▪ +0,02 % per °C