Temperature Sensors T

Detailbild


Temperature Sensor PPC-04/12-T

▪ Screw-in version, measures current temperatures directly in the pipeline
▪ Rod-type version (-TSH), especially designed to determine the media temperatures in tanks and containers
▪ 5-pin connection
▪ Input signal: 0 ...3 V DC
▪ Output signal: 7 ...12 V DC

CAN Temperature Sensor PPC-CAN-T

▪ CAN version
▪ Indication of the sensor status via LED
▪ 5-pin SPEEDCON connection plug
▪ CANopen protocol profile DS301, Typ 2.0A with manufacturer-specific additions
▪ LSS service DS305 v2.0
▪ Output signal: CAN bus

Left column (copy 2)

Technical Data

▪ Measurement medium: liquids (consult STAUFF
  for use with aggressive media
▪ Calibration certificate on request

Materials
▪ Housing (T): Stainless Steel
▪ Gaskets (T): FPM (Viton®)
▪ Rod (TSH): Stainless Steel 1.4304
▪ Handle (TSH): Delrin

Weight
▪ T (M10x1): 70 g / .15 lbs
▪ T (G1/4): 55 g / .12 lbs
▪ TSH: 120 g / .26 lbs

Connection:
▪ a) STAUFF Test connection SGV-16S-G-C6F in the
  pipeline (only M10x1)
▪ b) Screw-in thread (T): M10 x 1  or G1/4
▪ c) Screw-in thread (TSH): M10

Ambient Conditions (Screw-in Version)
▪ Media temperature: -40 °C ... +150 °C / -40 °F ... +257 °F
▪ Ambient temperature: -40 °C ... +85 °C / -40 °F ... +185 °F
▪ Storage temperature: -40 °C ... +85 °C / -40 °F ... +185 °F

Ambient Conditions (Rod-type Version)
▪ Media temperature: -25 °C ... +150 °C / -13 °F ... +257 °F
▪ Ambient temperature: -25 °C ... +70 °C / -13 °F ... +158 °F
▪ Storage temperature: -25 °C ... +80 °C / -13 °F ... +176 °F

Measuring Range
▪ Measuring Range (T): -40 °C ... +125 °C / -40 °F ... +302 °F
▪ Measuring Range (TSH): -25 °C ... +125 °C / -13 °F ... +257 °F
▪ Operating pressure (T): 630 bar / 9137 PSI
▪ Maximum pressure (T): 800 bar / 11603 PSI
▪ Burst pressure (T): 2150 bar / 31183 PSI
▪ Accuracy: ±1 % FS
▪ Accuracy (CAN): ±0,66 % FS

Left column (copy 2)

Accessories

Temperature Sensor:
  A PPC-04/12-CAB3 (3 m / 9.84 ft) Connection Cable is
  needed to connect the sensor to the current Hydraulic
  Testers.
  A PPC-04/12-CAB5-EXT (5 m / 16.40 ft) Extension Cable
  is also available as an option.

▪ PPC-04/12-T-M02 with SGV-16S-C6F
  Temperature Sensor with STAUFF Test connection
  SGV-16S-G-C6F in the pipeline